1,207 research outputs found

    A Readout System for the STAR Time Projection Chamber

    Full text link
    We describe the readout electronics for the STAR Time Projection Chamber. The system is made up of 136,608 channels of waveform digitizer, each sampling 512 time samples at 6-12 Mega-samples per second. The noise level is about 1000 electrons, and the dynamic range is 800:1, allowing for good energy loss (dE/dxdE/dx) measurement for particles with energy losses up to 40 times minimum ionizing. The system is functioning well, with more than 99% of the channels working within specifications.Comment: 22 pages + 8 separate figures; 2 figures are .jpg photos to appear in Nuclear Instruments and Method

    Correcting for Distortions due to Ionization in the STAR TPC

    Full text link
    Physics goals of the STAR Experiment at RHIC in recent (and future) years drive the need to operate the STAR TPC at ever higher luminosities, leading to increased ionization levels in the TPC gas. The resulting ionic space charge introduces field distortions in the detector which impact tracking performance. Further complications arise from ionic charge leakage into the main TPC volume from the high gain anode region. STAR has implemented corrections for these distortions based on measures of luminosity, which we present here. Additionally, we highlight a novel approach to applying the corrections on an event-by-event basis applicable in conditions of rapidly varying ionization sources.Comment: 6 pages, 7 figures, proceedings of the Workshop on Tracking in High Multiplicity Environments (TIME 05) in Zurich, Switzerland, submitted to Nucl. Instr. and Meth.

    Laser frequency locking by direct measurement of detuning

    Full text link
    We present a new method of laser frequency locking in which the feedback signal is directly proportional to the detuning from an atomic transition, even at detunings many times the natural linewidth of the transition. Our method is a form of sub-Doppler polarization spectroscopy, based on measuring two Stokes parameters (I2I_2 and I3I_3) of light transmitted through a vapor cell. This extends the linear capture range of the lock loop by up to an order of magnitude and provides equivalent or improved frequency discrimination as other commonly used locking techniques.Comment: 4 pages, 4 figures Revte

    Observation of modified radiative properties of cold atoms in vacuum near a dielectric surface

    Full text link
    We have observed a distance-dependent absorption linewidth of cold 87^{87}Rb atoms close to a dielectric-vacuum interface. This is the first observation of modified radiative properties in vacuum near a dielectric surface. A cloud of cold atoms was created using a magneto-optical trap (MOT) and optical molasses cooling. Evanescent waves (EW) were used to observe the behavior of the atoms near the surface. We observed an increase of the absorption linewidth with up to 25% with respect to the free-space value. Approximately half the broadening can be explained by cavity-quantum electrodynamics (CQED) as an increase of the natural linewidth and inhomogeneous broadening. The remainder we attribute to local Stark shifts near the surface. By varying the characteristic EW length we have observed a distance dependence characteristic for CQED.Comment: 6 pages, 6 figures, some minor revision

    Universal quantum computation and simulation using any entangling Hamiltonian and local unitaries

    Get PDF
    What interactions are sufficient to simulate arbitrary quantum dynamics in a composite quantum system? We provide an efficient algorithm to simulate any desired two-body Hamiltonian evolution using any fixed two-body entangling n-qubit Hamiltonian and local unitaries. It follows that universal quantum computation can be performed using any entangling interaction and local unitary operations.Comment: Added references to NMR refocusing and to earlier work by Leung et al and Jones and Knil

    Ï•\phi meson production in sNN\sqrt{s_{NN}} = 200 GeV Au+Au and pp collisions at RHIC

    Full text link
    We present the results for the measurement of ϕ\phi meson production in sNN\sqrt{s_{NN}} = 200 GeV Au+Au and pp collisions at the Relativistic Heavy Ion Collider (RHIC). Using the event mixing technique, spectra and yields are obtained from the ϕ→K+K−\phi\to K^{+}K^{-} decay channel for different centrality bins in Au+Au collisions and in pp collisions. We observe that the spectrum shape in Au+Au collisions depends weakly on the centrality and the shape of the spectrum in pp collisions is significantly different from that in Au+Au collisions. In Au+Au collisions, the extracted yield of ϕ\phi meson is flat as a function of rapidity; The of ϕ\phi, extracted from the fit function to the spectra, shows a different behavior as a function of centrality than that of π−\pi^-, K−K^- and pˉ\bar{p}Comment: Proceedings for the 7th International Conference on Strangeness in Quark Matte
    • …
    corecore